Download netaxs123 version 5






















NetAXS 6. The new release of the product is now available across the Americas. Share to:. Related Articles. Honeywell expands line of fire-lite addressable fire alarm control panels. Technology knowledge gap leads to challenges in smart building market. Getting Started Reading the Select Panel 1.

Configuring via the Web Server 2. Configuring via the Web Server Overview 2. Table Configuration Task Sequence To perform this task Click this heading 1. Configure the doors: Readers Outputs Inputs 4. Configure the access levels.

Click this heading 5. Configuring via the Web Server Configuring the System 2. Panel initiates connection to host. Panel currently does not support encryption. None — Select this if you are using web mode. Comms Type Specifies the type of communications. This is the recommended communications type. Normally used in troubleshooting only. Port Number Specifies the port number for the Ethernet port default is Enabled — Causes the gateway to automatically broadcast its time to downstream panels in order to time-synchronize the loop.

This setting is in Loop minutes, range Baud Rate Specifies the transmission rate bits per second among the downstream panels on the loop. Force Baud Reset — Tells all downstream panels to change to the selected Downstream baud rate.

This saves the user from having to go to each panel individually. These settings require a reboot to take effect. This setting requires a reboot to take effect. No reboot is required. Positions 8 and 9: RS line termination. Both ON: Terminated. Position Reserved. See www. Boot Time Displays the time that power was applied to the panel. Reset Reboots the panel. A reset does not change the current configuration in the database.

If the sequence is invalid, an anti-passback violation is generated and the card holder and is denied access. Local — Enforces anti-passback only at doors configured locally to the panel controlling the original card read. Forgiveness — Causes all system codes to be reset at midnight every day. This enables a card holder who exited the building in the evening without using his card to use his card for entry the following morning. Gateway Panel Addr Displays the panel address of the Gateway panel, or the panel directly connected to the host system.

Web Session Timeout Activates a web session timeout after the specified time period has elapsed. Define the time period either in minutes or in hours. Enter the number in the box, then select either minutes or hours Free Egress Enabled — Configures the panel for free egress. When enabled Default , the panel automatically configures inputs 1, 9, and 13 to act as egress inputs for Doors 1, 2, and 3 respectively. If disabled, those inputs 1, 9, and 13 can be used as general inputs.

Duress requires both a PIN value and Card number to be recognized, as described below. This feature is available only when the reader is configured with a "Card and Pin" access mode see Reader A Tab , page This parameter is set to Disabled by default.

See Outputs Tab , page 48 for the output configuration. During normal operation, the duress output does nothing. To energize the output for example, during a robbery , the card holder presents his card to a reader that is configured for Card and PIN access see Reader A Tab , page For example, if the PIN is , the card holder would enter either or Even though the PIN is incorrect, the door will still open normally, but the duress output pulses and an alarm is generated.

In this way, the card holder notifies others without detection by the unauthorized person. Note : A PIN ending in 0 for example, will only trip a duress output when a 1 is used in place of the 0 for example, Continuous Card Reads Enabled — Enables continuous card reading while the output is being energized. When this option is not enabled, a reader will not be able to read a second card during the pulsing of the output caused by the previous card read.

This parameter is set to Enabled by default. When this parameter is enabled, the LED should be solid red and then turn green after two seconds by default. To delete a site code : 1. To delete all site codes : 1. For example: Fri Oct 30 Format 12 hour — The hour day is divided into two hour halves, AM and PM; each half is numbered New Date Specifies a new date to be the current date.

Use the drop-down lists to set the month and date, and click the calendar icon to specify a different year. New Time Specifies a new time to be the current time. Use the drop-down lists to set the hour, minute, and AM or PM. Geographic Time Select the geographic time zone in which the panel will Zones operate. Enabled — Select to enable the specified machine to be the active time server. Update Interval — Specifies the interval of time between each automated synchronization.

Recommended value is once per day. The panel starts to update time as soon as it is enabled and successfully connects to the Time Server; it will continue to update according to the interval selected from that start point.

Click Add Time Zone. To delete a time zone : Caution: Do not delete a time zone that is currently in use. In the Tz column, click the number of the time zone you want to delete. Then, with the Link Time Zone feature, you can link them so that they all work together: 1. Configuring via the Web Server Configuring Time Management Each Holiday added is considered a full day, extending from midnight to midnight. To modify a holiday : 1.

To delete a holiday : 1. Configuring via the Web Server Configuring the Doors 2. Steps: 1. For each access mode, you must also select a time zone from the drop-down list. The time zone is the schedule by which the access mode is effective. Disabled — Disabled mode puts the reader in a state where all card reads are ignored, with the exception of a VIP card, which is allowed access.

Contact and Egress will report, but Egress will not cause the door to open. Lockdown — Ignores all card reads except from a VIP card , denies door entry but allows egress. You can perform the card read and PIN entry in either sequence. You must make the second entry within 10 seconds of the first entry, in either sequence. Supervisor — A mode that enables a supervisor to enter without allowing general access. When this mode is enabled, the reader LED changes color four times per second usually red then green.

When the supervisor presents his card during the time zone just once, he gains access but does not enable general access. If the supervisor presents his card again within 10 seconds, he enables general access and the LED displays a steady red.

After the supervisor presents his card twice to allow general access, he can disable the general access for the time zone by presenting his card again twice consecutively.

The LED resumes rapid flashing between red and green. VIP cards do not need a supervisor card to gain access. When this mode is enabled, the reader LED changes color four times per second usually red then green and employees must be accompanied by a supervisor to gain entry.

When the supervisor presents his card, the LED goes solid red for 10 seconds, pending an employee credential. When the employee credential is swiped within 10 seconds of the supervisor card swipe, the door opens to admit the employee and the LED returns to rapid flashing. If the time expires and there is no employee credential swipe, the LED returns to rapid flashing and the reader returns to escort mode.

A supervisor can gain entry by simply swiping the card twice. Unlike Supervisor mode, the Escort mode when active cannot be disabled during its time zone; a supervisor is required for all employee access during Escort mode time zone. Enabled - Enables the anti-passback feature. Out - Applies to readers located inside the anti-passback-controlled area. Card holders use these readers when attempting to exit the anti-passback-controlled area. In - Applies to readers located outside the anti-passback-controlled area.

Card holders use these readers when attempting to enter the anti-passback-controlled area. This PIN opens the door, but it also triggers the designated duress output and produces an alarm event. You can only view or download manuals with. Sign Up and get 5 for free. Upload your files to the site. You get 1 for each file you add. Get 1 for every time someone downloads your manual. Buy as many as you need.

View and download manuals available only for. Register and get 5 for free. Upload manuals that we do not have and get 1 for each file. Get 1 for every download of your manual. Buy as much as you need. Maintaining Cards, page 56 and. Enabled — Causes the gateway to. Force Baud Reset — Tells all downstream. Positions ON position specify the RS address. When this switch changes state OFF to.

Positions 1 and 2: RS 2-line termination. Both ON:. Displays the time that power was applied to the panel. Reboots the panel. A reset does not change the current. If the sequence is invalid, an. Forgiveness — Causes all system codes to be reset at. This enables a card holder who exited. Displays the panel address of the Gateway panel, or the panel.

Activates a web session timeout after the specified time. Define the time period either in minutes. Enter the number in the box, then select either. Enabled — Configures the panel for free egress. If disabled, those inputs 1, 9, and 13 can be used.

Duress requires both a PIN value. When this feature is enabled, a Duress Output option at the. You then need to assign the selected output--a.

For example, if the. PIN is , the card holder would enter either or Even though the PIN is incorrect, the door will still open. In this way, the card holder notifies others without. When this option is not enabled, a reader. This parameter. When this parameter is enabled, the LED should. Specifies any information field you might want to put on a.

The user who. Select the geographic time zone in which the panel will. Find the appropriate continent, and then identify the. In the. United States, you might find these time zone associations. The panel starts to update time as soon as it is. Specifies the validation conditions required at the door. For each access mode, you must. The time. The runtime includes everything you need to run. NET applications. The runtime is also included in the SDK.

NET Core Runtime 5. NET Core Module v2 NET Core 5. NET Desktop Runtime 5. Downloads for. NET Runtime 5. If using an older patch release, you should upgrade to get these fixes. Release notes Latest release date These releases are supported for production use since they have a go-live license.

Full version 5.



0コメント

  • 1000 / 1000